Standard Series Desiccant Breathers
Des-Case Standard breathers provide simple, yet dependable protection from moisture and particulate contamination in lubricants and equipment across multiple industries and applications. These versatile breathers are five times more effective than the leading non-desiccant breathers, providing optimal defense against humidity for your applications.
Product Specs |
DC-BB |
DC-1 |
DC-2 |
DC-3 |
DC-4 |
---|---|---|---|---|---|
Unit Height (in / mm) | 3.90 / 99.06 | 5.31 / 134.9 | 6.125 / 155.6 | 8.125 / 206.4 | 10.125 / 257.2 |
Unit Diameter (in / mm) | 2.52 / 64.1 | 2.52 / 64.1 | 4 / 101.6 | 4 / 101.6 | 4 / 101.6 |
Connection Size | 3/8" Multi-Fit (NPT, BSPP, BSPT) | 3/8" Multi-Fit (NPT, BSPP, BSPT) | 1" Multi-Fit (NPT, BSPT, NPSM) | 1" Multi-Fit (NPT, BSPT, NPSM) | 1" Multi-Fit (NPT, BSPT, NPSM) |
Amount of Silica Gel (lbs / kg) | 0.13 / .058 | 0.28 / .127 | 0.66 / 0.30 | 1.22 / 0.56 | 1.88 / 0.84 |
Adsorption Capacity (fl oz / ml) | 0.79 / 23.3 | 1.68 / 49.7 | 4.00 / 118.2 | 7.45 / 220.3 | 11.3 / 333 |
Max. Flow Rate (cfm) | 4.55 @ 1 psid | 4.16 @ 1 psid | 16 @ 1 psid | 16 @ 1 psid | 16 @ 1 psid |
Max. Flow Rate (lpm) | 128.84 | 117.8 | 453 | 453 | 453 |
Filter Efficiency | 3µ absolute (β₃≥200) | 3µ absolute (β₃≥200) | 3µ absolute (β₃≥200) | 3µ absolute (β₃≥200) | 3µ absolute (β₃≥200) |
Operating Temp. Range (°F) | -20° to 200° | -20° to 200° | -20° to 200° | -20° to 200° | -20° to 200° |
Operating Temp. Range (°C) | -29° to 93° | -29° to 93° | -29° to 93° | -29° to 93° | -29° to 93° |
Model | Max. Airflow at 1 psid | Recommended Max. Volume | |
---|---|---|---|
Gearbox / Storage Tank | Hydraulic Reservoir | ||
DC-BB | 4.55 cfm / 129 lpm | 15 gal / 57 L | 2 gal / 8 L |
DC-1 | 4.16 cfm /118 lpm | 35 gal / 132 L | 5 gal / 19 L |
DC-2 | 16 cfm / 453 lpm | 200 gal / 757 L | 60 gal / 227 L |
DC-3 | 16 cfm / 453 lpm | 350 gal / 1325 L | 100 gal / 379 L |
DC-4 | 16 cfm / 453 lpm | 500 gal / 1893 L | 200 gal / 757 L |
APPLICATIONS
- Totes
- Transformers
- Storage Tanks
- Hydraulics
The desiccant breather replaces the standard dust cap or OEM breather cap on equipment. As air is drawn into equipment through the breather, the layered filter elements remove particulate while the desiccant beads strip harmful moisture. While in service or during shut-down, the desiccant beads attract moisture from inside the equipment reservoir, actively drying the equipment.
Seeing Pink?
A pink breather means it has done its job keeping moisture out of your lubricants. Time to replace the breather with a new one.
Description | Part Number |
---|---|
1" FNPT x 1" Slip Fit Adapter | DC-10-S |
1" Threaded Adapter | DC-10 |
1" Male Threaded x 1" Female Threaded Adapter | DC-10-T |
Bell Reducer 1" to 3/4"-Slip Fit | DC-17 |
1"-3/4" Female to Male Threaded Adapter | DC-17-T |
1"-1/4" Brass, Threaded Reducer/Adapter | DC-18 |
Threaded Flange Adapter | DC-12-T |
Threaded Flange Adapter with Gasket | DC-12-TG |
Bayonet Adapter | DC-15-T |
3/4" NPT Vent Valve Adapter for Standard and VentGuard Breathers | DC-SDVA-12M |
1" NPT Vent Valve Adapter for Standard and VentGuard Breathers | DC-SDVA-16M |
- Removes moisture in the headspace of equipment
- Eliminates rust-forming condensation
- Prevents sludge deposits and water-contaminated oil
- Prevents contamination ingress
- Provides longer lubricant life
- Reduces wear and tear on equipment, prolongs life
APPLICATION | AIR VENT HOLES TO OPEN | |
---|---|---|
Gearbox | 2 | |
Hydraulic Pump: 0-4 cfm @ 1 PSID / 0-113 L/mn | 2 | |
Hydraulic Pump: 4-8 cfm @ 1 PSID / 113-226 L/mn | 4 | |
Hydraulic Pump: 8-12 cfm @ 1 PSID / 226-339 L/mn | 6 | |
Hydraulic Pump: 12-16 cfm @ 1 PSID / 339-452 L/mn | 8 |